Prime Rating at rated rpm ( as per ISO8528)1
kVA
1500 HD
kW
1000
Genset Model
KG1-1500WS
Frequency
Hz
50
Power factor
lagging
0.8
Voltage (with Three Phase Supply)
V
415 3Ø
Governing class ( As per ISO 8528 Part-V)
G3
Noise level
dBA
Contact Kirloskar Oil Engines For Details
Fuel Consumption* At 100 % Load
Ltrs/Hr
310
At 75 % Load
230
At 50 % Load
157
Fuel Tank Capacity
Ltrs
880
Dry weight of genset with canopy (approx..)^
Kg
13075+
Overall dimensions of genset (L x W x H)^

mm
5650+ x 2300+ x 2660+
Electrical Battery starting voltage
Volts-DC
24
ENGINE
Engine Model
12K4300 E1
Rated output (Prime Continuous rating as per ISO 8528-1)
kW
1294
HP
1760
No. of cylinder
Number
12
Cubic capacity 2
Ltrs
51.73
Bore x Stroke
mm
170 x 190
Rated Speed
RPM
1500
Aspiration
NA/TC/TA
TA
Lube Oil change period
hrs.
500
Lube oil Sump Capacity
Ltrs
265
Coolant Capacity
Ltrs
210
ALTERNATOR
Insulation Class
Class H
Ingression Protection
IP 23
Alternator Efficiency (at 100% load) 0.8 pf**
95.4
Alternator Efficiency (at 75% load) 0.8 pf**
95.8
Max Voltage Dip at Full Load 0.8 pf Lag
< 20 %
Max Time to build up rated voltage at Rated RPM < 1 sec provided engine reach the rated speed
Short Circuit With Stand Time
Sec
3 Times rated current for *10 sec*
Overload With Stand Capacity
%
10% overload for one hour once in 12 hours
For intermediate ratings, kindly contact nearest Kirloskar office
For Site Conditions other than standard operating conditions consult Kirloskar Oil Engines ltd.

Notes
^ Tolerances Apply     *Efficiency of Alternator as per standards IEC60034-1
+ Weight & dimensions are for open genset For canopised genset, please contact kirloskar Oil Engines Ltd.
$ These Weight are for handling & transportation only, +- 5 % tolerance apply
# With 0.845 Specific Gravity of diesel ( 5% Tolerance )

7 Easy steps for a happy genset ownership

  • Insist on a load-study
  • Select the Genst rating as per the load-study and with sufficient margin for future load expansion
  • Apply site-selection duideliness carefully
  • Insist on installation in line with Kirloskar Green guideliness
  • Ensure adequate size and proper connection of cables
  • Understand the genset operation & Maintenance procedures during commissioning
  • Follow routine maintenance protocols through authorized Kirloskar Green Service dealers

Prime rating and Stand‐by rating1

‘Prime power’ is designed for Unlimited hours, as compared to 'Emergency stand-by' designed for 200 hours in a year. Prime rated Gensets also permit 10% temporary overloading. Users need to carefully select the Genset rating to meet their requirement. Kirloskar offers Prime power as a standard offer. Contact Kirloskarfor stand-by ratings.

Engine capacity does matter2

Engine capacity (cc) plays a vital role in Genset performance. Higher engine capacity leads to a robust and stable Genset performance.

Higher engine capacity also enables the Genset to respond quickly & positively to sudden load additions.

1.Canopy

  • Ease of Access and Serviceability
  • Aesthetically designed, weather and sound resistant enclosure
  • Insulation conforms to UL94-HF1 class for flammability

2.Controller

  • Microprocessor based
  • Graphical LCD display
  • Best in class monitoring and diagnostic capability
  • Integrable with AMF, synchronization & communication configurations

3.Engine

  • O2E Series: Low emission, high efficiency engines
  • Compact, Robust and Rugged Design
  • 500 hours lube-oil change period
  • Integral set - mounted radiator system, designed & tested for 500C ambient temperature

4.Alternator

  • Best In Class Efficiency
  • Special Windings to Reduce Harmonics
  • Vacuum Pressure Impregnation and epoxy gel coating on the winding

Best-in-class Fuel Efficiency

Kirloskar Green Gensets offer a unique combination of CPCB norm compliance and enhanced fuel efficiency. Across the range, KirloskarGreen Gensets offer substantial savings in fuel cost

O2E Series (Optimal Operating Efficiency):

Genset ratings are selected based on the present load and future expansion. Fuel efficiency of most Gensets is optimized at the full rating of the Genset

In practice, Gensets rarely get loaded to full capacity. Power demand variations across day & night, weekdays & weekends, summer & winter lead to an average 50-70% loading on Gensets.

Considering this practical situation, Kirloskar has extended fuel efficiency optimization from 100%, right up to 50% of rated load. Combination of best-in-class fuel efficiency & O2E provides a double advantage

Genset Monitoring at Your Finger Tips

Kirloskar Green gensets are enabled with Kirloskar remote monitoring system which shares Real Time Genset information and location Services. It can be accessed via mobile device or desktop. Kirloskar remote monitoring system also highlights any parameter which needs special attention. These critical indication alerts are sent to user mobile via text message. It also alerts nearest services dealer is case of any emergency break-down.

Peace-of-mind Ownership

Kirloskar Green Gensets have always been preferred for their robust design and reliability over long usage life.

Kirloskar Green range carries the confidence of well-established and proven engine platforms. For compliance to revised CPCB norms, Kirloskar has carefully selected those technologies which not only retain, but enhance Gensets durability and on-site serviceability.

Thus, Kirloskar Gensets offer you many years of trouble-free performance; backed by the assurance of prompt support. Peace-of-mind driven by product reliability and low cost of ownership.

State of the art Genset Controller

Kirloskar Green Genset put the command in your hands. Micro-processor based Genset controllers display a host of genset parameters and put all controls at your fingertips.

Monitoring Features:
  • Phase Voltages & Currents, Frequency, Reverse power, Genset kVA, kW, kWh, kVAr, Power Factor, Canopy Temperature
  • Lube oil Pressure, Engine Temperature, RPM, Run Hours,Number of starts, Fuel Level, Auto / Manual Stop, Battery charge condition,AMF feature
Diagnostic Features :
  • Battery charging failure, Over/Under speed, Over Current, Over/Under Voltage, Over kW, Phase Seq., Phase missing, Mains Under voltage, Earth Fault trip, Fuel usage Alarm
  • Low lube oil Pressure, High Engine Temperature, Low/High battery voltage, Low Fuel Level, Over Crank protection, Routine maintenance indicator, Genset Test Facility, Mains Frequency
Optional Features :
  • Modbus Communication
  • Synchronization